1U PCIe Riser 2 assembly
(2 x low profile; x8 or x16)
1U PCIe Riser 1 assembly
(1x low profile; x16)
00000
00000
00000
00000
00000000
00000000
00000000
00000000
Bracket
00
00
Figure 99. PCI riser-card assembly installation (4)
Step 8.
Reinstall the cover (see “Replacing the cover” on page 120).
Step 9.
Slide the server into the rack.
Step 10. Reconnect the power cords and any cables that you removed.
Step 11. Turn on the peripheral devices and the server.
Removing an adapter
Use this information to remove an adapter.
To remove an adapter, complete the following steps:
Step 1.
Read the safety information that begins on “Safety” on page v and “Installation guidelines” on
page 116.
Step 2.
Turn off the server and peripheral devices and disconnect all power cords; then, remove the
cover (see “Removing the cover” on page 119).
Step 3.
Disconnect any cables from the adapter.
Step 4.
Grasp the PCI riser-card assembly at the blue tabs and lift to remove the PCI riser-card assembly.
Step 5.
Place the PCI riser-card assembly on a flat and static-protective surface.
176
Lenovo System x3550 M5 Installation and Service Guide
Summary of Contents for System x3550 M5
Page 1: ...Lenovo System x3550 M5 Installation and Service Guide Machine Type 8869 ...
Page 6: ...iv Lenovo System x3550 M5 Installation and Service Guide ...
Page 66: ...52 Lenovo System x3550 M5 Installation and Service Guide ...
Page 298: ...284 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1120: ...1106 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1124: ...1110 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1132: ...Taiwan BSMI RoHS declaration 1118 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1134: ...1120 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1142: ...1128 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1143: ......
Page 1144: ......