User manual of EL8-EC***F AC Servo
175
AF unL Front panel unlock
Auxiliary
AF unL
Front panel
unlock
Operation
unL -
Initialization
S
FinSh
is displayed after press
▲
once. Front panel unlocked
FinSh
AF ACL Clear alarm
Alarm can be cleared using this auxiliary function but before that, the error needs to be
solved and driver needs to be restarted.
Auxiliary function
AF ACL
Clear alarm
Operation
ACL -
Initialization
S
FinSh
Press
▲
once.
FinSh is displayed once completed.
For alarms that can be cleared using this function, please refer to table in Chapter 8.
AF of1 - AF of3 Analog input AI1-3 zero drift correction
Auto adjustment of analog input zero drift settings
Analog
input
Parameter (Zero drift
settings)
AI1
Pr4.22
AI2
Pr4.25
AI3
Pr4.28
Auxiliary function
AF of1
AI1 Zero drift
correction
Operation
of1 -
Initialization
S
StArt
FinSh
Start correction
Completed
Press
▲
once to start correct(displays
StArt)
FinSh is displayed once completed.