User manual of EL8-EC***F AC Servo
263
position comparison properties value set.
Pr3.74
Label
Position comparison 1 & 2
attributes value
Mode
F
Range
0~32767
Unit
Comma
nd unit
Default
0
Index
2332h –
2373h
Activation
Immediate
Bit
Position comparison 1
0
Positive traversal comparison. 0=OFF,1=ON
1
Negative traversal comparison. 0=OFF,1=ON
2~5
Reserved
6
Output property settings
:
=0
:
Pulse mode
=1
:
Flipping mode
7
DO1
8
DO2
9
DO3
10~12
Reserved
13
Frequency divider Phase A output
14
Frequency divider Phase B output
15
Frequency divider Phase Z output
Bit
Position comparison 2
16
Positive traversal comparison. 0=OFF,1=ON
17
Negative traversal comparison. 0=OFF,1=ON
18~21
Reserved
22
Output property settings
:
=0
:
Pulse mode
=1
:
Flipping mode
23
DO1
24
DO2
25
DO3
26~28
Reserved
29
Frequency divider Phase A output
30
Frequency divider Phase B output
31
Frequency divider Phase Z output
Pr3.75~
Pr3.94
Label
Position comparison x & y
attributes value
Mode
F
Range
0x0~0xFF
FFFFFF
Unit
-
Default
0
Index
2375h-
2394h
Activation
Immediate