User manual of EL8-EC***F AC Servo
98
Activation
Immediate
Pr4.06
Label
Input selection DI7
Mode
F
Range
0x0~0xFF Unit
—
Default
0x4
Index
2406h
Activation
Immediate
Pr4.07
Label
Input selection DI8
Mode
F
Range
0x0~0xFF Unit
—
Default
0x0
Index
2407h
Activation
Immediate
Digital input DI allocation using hexadecimal system
Input
Symbol
Set value
0x60FD
(bit
)
Normally
open
Normally
close
Invalid
—
0h
-
×
Positive limit switch
POT
1h
81h
Bit1
Negative limit switch
NOT
2h
82h
Bit0
Clear alarm
A-CLR
4h
-
×
Forced alarm
E-STOP
14h
94h
×
Home switch
HOME-SWITCH
16h
96h
Bit2
·
Please don’t set anything other than listed in table above.
·
Normally open: Valid when input = ON Normally close: Valid when input = OFF
·
Er210 might occur if same function is allocated to different channels at the same time
·
Channel that has no value doesn’t affect driver motion.
·
Front panel is of hexadecimal system.
·
Pr4.00 – Pr4.07 corresponds to DI1 – DI8. External sensors can be connected if the
parameters are all set to 0. Controller will read 60FD bit4 – 11 to get DI1 – DI8 actual status.
Pr4.10
Label
Output selection DO1
Mode
F
Range
0x0~0xFF Unit
—
Default
0x1
Index
2410h
Activation
Immediate
Pr4.11
Label
Output selection DO2
Mode
F
Range
0x0~0xFF Unit
—
Default
0x3
Index
2411h
Activation
Immediate
Pr4.12
Label
Output selection DO3
Mode
F
Range
0x0~0xFF Unit
—
Default
0x4
Index
2412h
Activation
Immediate
Digital output DO allocation using hexadecimal system.
Output
Symbol
Set value
Normally
open
Normally close
Master device control
—
00h
-
Alarm
ALM
01h
81h
Servo-Ready
S-RDY
02h
82h