User manual of EL8-EC***F AC Servo
65
1
:
As normal, continue homing process
5400
01
Set
synchronization
cycle minimum
value
us
250
125
1000
5400
02
Set
synchronization
cycle maximum
value
us
10000
4000
20000
5500
01
Absolute encoder
multiturn number
r
-
-
-
-
02
Encoder single
turn position
Pulse
-
-
-
-
03
Encoder feedback
position 32 bit low
Pulse
-
-
-
-
04
Encoder feedback
position 32 bit
high
Pulse
-
-
-
-
05
The actual
mechanical
position 32 bit low
Unit
-
-
-
-
06
The actual
mechanical
position 32 bit
high
Unit
-
-
-
-
07
Number of
encoder
communication
exceptions
-
-
-
-
5501
01
Motor Speed
r/min
-
-
-
-
02
Speed of position
command
r/min
-
-
-
-
03
Speed command
r/min
-
-
-
-
04
Actual torque
0.1%
-
-
-
-
05
Torque command
0.1%
-
-
-
-
06
Relative position
error
Pulse
-
-
-
-
07
Internal position
command
Pulse
-
-
-
-
08
Overload ratio
0.1%
-
-
-
-
09
Discharge load
rate
0.1%
-
-
-
-
0A
Inertia ratio
%
-
-
-
-
0B
Actual positive
torque limit value
0.1%
-
-
-
-
0C
Actual negative
torque limit value
0.1%
-
-
-
-
0D
U phase current
detect value
0.1%
-
-
-
-
0E
W phase current
detect value
0.1%
-
-
-
-
5502
01
DI input signal
-
-
-
-
-
02
SO output signal
-
-
-
-
-
03
Reserved
-
-
-
-
-
04
Reserved
-
-
-
-
-
05
Bus voltage
V
-
-
-
-