User manual of EL8-EC***F AC Servo
130
Index
607Fh
Label
Maximum protocol
velocity
Unit
Comman
d unit/s
Structure
VAR
Type
UInt 32
Access
R
W
Mappin
g
RPDO
Mode
PP/HM/P
V/CST
Range
0~214
74836
47
Default
21474836
47
To set maximum allowable velocity. Limited by 6080.
Index
6080h
Label
Maximum motor
velocity
Unit
R/min
Structure
VAR
Type
UInt 32
Access
R
W
Mappin
g
RPDO
Mode
F
Range
0~214
74836
47
Default
6000
To set the maximum allowable motor velocity.
Index
6081h
Label
Profile velocity
Unit
Comman
d unit/s
Structure
VAR
Type
UInt 32
Access
R
W
Mappin
g
RPDO
Mode
PP
Range
0~214
74836
47
Default
10000
To set target velocity. Limited by 607Fh.
Index
6083h
Label
Profile acceleration
Unit
Comman
d unit/s²
Structure
VAR
Type
UInt 32
Access
R
W
Mappin
g
RPDO
Mode
PP/PV
Range
1~214
74836
47
Default
10000
To set motor acceleration
Index
6084h
Label
Profile deceleration
Unit
Comman
d unit/s²
Structure
VAR
Type
UInt 32
Access
R
W
Mappin
g
RPDO
Mode
CSP/CSV
/PP/PV/H
M
Range
1~214
74836
47
Default
10000000
To set motor deceleration
Index
6085h
Label
Emergency stop
deceleration
Unit
Comman
d unit/s²
Structure
VAR
Type
UInt 32
Access
R
W
Mappin
g
RPDO
Mode
PP/PV
Range
1~214
74836
47
Default
10000