User manual of EL8-EC***F AC Servo
105
To set the amplification of AO1, actual voltage output = amplification x theoretical voltage
Pr4.67
Label
AO1 communication setting Mode
F
Range
-10000~10
000
Unit
-
Default
0
Index
2467h
Activation
Immediate
Available when AO1 = 0xB, AO1 output = output setting of Pr4.67
Pr4.68
Label
AO1 offset
Mode
F
Range
-10000~10
000
Unit
-
Default
0
Index
2468h
Activation
Immediate
To set AO1 offset value.
Pr4.69
Label
AO2 output mode
Mode
F
Range
0~10
Unit
-
Default
0
Index
2469h
Activation
Immediate
Set value
Description
【
0
】
Negative/Positive value: -10~10V
1
Absolute value output: 0~10V
Other
Reserved
Pr4.70
Label
AO2 signal
Mode
F
Range
0x0~0x7FF
FFFFF
Unit
-
Default
0
Index
2470h
Activation
Immediate
Bit 0 – 15: AO signal source; Bit 16 – 31: DO extension channel
Bit0~Bit15
Signal source
0x0
-
0x1
Motor rotational speed
(
V/krpm
)
0x2
Position command velocity
(
V/krpm
)
0x3
Internal position command velocity
(
V/krpm
)
0x4
Torque command
(
0.03V/0.01
)
0x5
Position command deviation
(
mV/Command unit
)
0x6
Position command deviation
(
mV/Encoder unit
)
0x7
Analog 1
(
V/V
)
0x8
Analog 2
(
V/V
)
0x9
Analog 3
(
V/V
)
0xA
Extension DO
(
0V/5V
)
0xB
As per Pr4.72
Bit 16 – 31: Only available when AO signal source = 0xA
Bit16~Bit31
Channel
01h
Alarm output
02h
Servo ready
03h
External brake released
04h
Positioning completed