User manual of EL8-EC***F AC Servo
107
Range
0~100
Unit
-
Default
5
Index
2478h
Activation
Immediate
To select warning signal for warning indicator light 1
Set value
Signal
【
0
】
None
1
Negative limit
2
Battery low voltage
3
Overload
4
Torque limit
5
Positive limit
other
Reserved
During normal operation, warning indicator light will be lighted in a cycle.
3.2.6
【
Class 5
】
Extension settings
Pr5.04
Label
Driver prohibition input
settings
Mode
F
Range
0~2
Unit
—
Defaul
t
0 Index
2504h
Activation
Immediate
To set driver prohibition input (POT/NOT): If set to 1, no effect on homing mode.
Set value
Explanation
0
POT
Positive direction drive prohibited
NOT
Negative direction drive prohibited
1
POT and NOT invalid
2
Any single sided input from POT or NOT might cause Er260
In homing mode, POT/NOT invalid, please set object dictionary 5012-04 bit0=1
Pr5.06
Label
Servo-off mode
Mode
F
Range
0~5
Unit
—
Default
0
Index
2506h
Activation
After restart
To set servo driver disable mode and status.
Set value
Explanation
Mode
Status
0
Servo braking
Dynamic braking
1
Free stopping
Dynamic braking
2
Dynamic braking
Dynamic braking
3
Servo braking
Free-run
4
Free stopping
Free-run
5
Dynamic braking
Free-run