User manual of EL8-EC***F AC Servo
177
AF rSt Software reset
Software reset is used mainly on parameters modification that takes effect only after driver
restart.
Auxiliary function
AF rSt
Software
reset
Operation
rSt -
Initialization
S
Hold
▲
StArt
will be displayed to
start reseting
StArt
Start to reset
Reset completed
S 0
LED displayed will be off for 3s and back to
initialization page once completed.
AF_tun One click auto tuning
One click auto tuning can be applied by operating the front panel. Set simple movement
range and movement range has to be more than 0.5 motor revolution.
Auxiliary function
AF tUn
One click
Auto tuning
Operation
tUn ---
Initialization
S
Press
◀
to enter one click auto tuning.
srUon
will be displayed.
SrUon
Error
If driver is enabled
before
◀
is pressed,
error might occur
When
SrUon
is
displayed, hold
▲▼
to perform CCW/CW
motion for a suitable
movement range.
Position will be
showed after motion
stops.
P 30
n 30
CCW
▲
▼
CW
r 5
After setting movement range,
hold S to start tuning.
Hold S
t 5
Shows tuning progress in %.
Tuning done at 100. Hold M to
save the parameter. If user does
not want to save, hold
◀
to get
back to SrUon
t 100
Hold M
FinSh
FinSh
will be displayed
after saving completed.
Press
◀
to get back to SrUon.
Press
◀
again to get back to
initialization page