User manual of EL8-EC***F AC Servo
262
Pr5.74
Label
Position comparison starting
point
Mode
F
Range
1~42
Unit
-
Default
1
Index
2574h
Activation
Immediate
To set the starting point of position comparison.
Pr5.75
Label
Position comparison end point
Mode
F
Range
1~42
Unit
-
Default
1
Index
2575h
Activation
Immediate
To set the end point of position comparison.
Pr5.76
Label
No. of cycle for N cycles
comparison
Mode
F
Range
1~50000
Unit
-
Default
1
Index
2576h
Activation
Immediate
To set the number of cycles for N cycles comparison in position comparison.
Pr5.77
Label
Position comparison – set current
position as origin
Mode
F
Range
0~1
Unit
-
Default
0
Index
2577h
Activation
Immediate
Set Value
Description
【
0
】
Disable
1
Enable
(
Rising edge
)
Set origin for position comparison, set current position as origin at rising edge.
Pr5.78
Label
Position comparison – Offset to
origin
Mode
F
Range
-2
31
~2
31
-1
Unit
-
Default
0
Index
2578h
Activation
Immediate
To set offset value of position in comparison to origin set in Pr5.77
To set target position and its attributes for position comparison.
Pr3.32 –
Pr3.73
Label
Position comparison 1-42
target value
Mode
F
Range
-2
31
~ 2
31
Unit
Comma
nd unit
Default
0
Index
2323h
Activation
Immediate
When target position(value) is reached, position comparison output will be depended on the