User manual of EL8-EC***F AC Servo
192
Realising
limit
function
Acceleration(6083h)
Deceleration(6084h)
Quick stop
deceleration(6085h)
Mu
lt
ipl
ie
r
Software Limit(607Dh)
Polarity(2006h)
Protocol
position
track
generator
Mu
lt
ipl
ie
r
Max Velocity(6081h)
Realising
limit
function
Track output(606Bh)
Position[Uint]
Velocity[Uint/S]
Acc-/deceleration[:Uint/S
2
]
Internal command
position(6062h)
Realising
limit
function
Target Position(607Ah)
Related Parameters
Basic object
PDO
Index+Sub-Index Label
Data
Type
Access Unit
Notes
(RXPDO)
6040-00h
Control word
U16
RW
—
Required
607A-00h
Target position
I32
RW
Uint
Required
6081-00h
Max. velocity
U32
RW
Uint
Required
6083-00h
Acceleration
I32
RW
Uint /S
Optional
(TXPDO)
6041-00h
Status word
U16
RO
—
Required
603F-00h
Error code
U16
RO
Optional
6064-00h
Actual position feedback
I32
RO
Uint
Required
606C-00h
Actual velocity feedback
I32
RO
Uint /S
Optional
60F4-00h
Actual following error
I32
RO
Uint
Optional
6077-00h
Actual torque
I16
RO
0.1%
Optional
Extended object
Index+Sub-Index
Label
Data Type
Access
Unit
603F-00h
Error code
U16
RO
—
6060-00h
Operation mode
I8
RW
—
6061-00h
Displayed operation mode
I8
RO
—
6062-00h
Position demand value
I32
RO
Uint
606B-00h
Internal command speed
I32
RO
Uint
607D-01h
Min. software limit
I32
RO
Uint
607D-02h
Max. software limit
I32
RO
Uint