User manual of EL8-EC***F AC Servo
96
Pr3.23
Label
Zero speed clamp static
time
Mode
PV
CSV
Range
0~32767
Unit
ms
Default
0
Index
2323h
Activation
Immediate
To set delay time for zero speed clamp.
To prevent creeping at low speed, velocity command forced to 0 when velocity goes under Pr3.16
after time set in Pr3.23
Pr3.32 –
Pr3.73
Label
Position comparison 1-42
target value
Mode
F
Range
-2
31
~ 2
31
Unit
Comma
nd unit
Default
0
Index
2323h
Activation
Immediate
When target position(value) is reached, position comparison output will be depended on the
position comparison properties value set.
Pr3.74
Label
Position comparison 1 & 2
attributes value
Mode
F
Range
0~32767
Unit
Comma
nd unit
Default
0
Index
2332h –
2373h
Activation
Immediate
Bit
Position comparison 1
0
Positive traversal comparison. 0=OFF,1=ON
1
Negative traversal comparison. 0=OFF,1=ON
2~5
Reserved
6
Output property settings
:
=0
:
Pulse mode
=1
:
Flipping mode
7
DO1
8
DO2
9
DO3
10~12
Reserved
13
Frequency divider Phase A output
14
Frequency divider Phase B output
15
Frequency divider Phase Z output
Bit
Position comparison 2
16
Positive traversal comparison. 0=OFF,1=ON
17
Negative traversal comparison. 0=OFF,1=ON
18~21
Reserved
22
Output property settings
:
=0
:
Pulse mode