User manual of EL8-EC***F AC Servo
141
Holding brake wiring diagram
Li
ne F
ilt
er
Servo Drive
L1
L2
M
PG
B
K
Brake Relay
BK-RY
DC 24V
Holding
brake
Encoder
Motor
U
W
V
Single Phase
220VAC
CN2
CN1
DO1+(BRK-OFF+)
24VDC brake power
supply
PE
DO1-(BRK-OFF-)
L1C
L2C
Servo drive
P
SG
EN
Holding
brake
Encoder
Motor
U
W
V
CN2
BR+
BR-
PE
External 24VBrake 24V
Brake 0V
Li
ne f
ilt
er
L1
L2
Single Phase
220VAC
L1C
L2C
1. Using internal holding brake output port X3 (Easy wiring, no need for an extra relay)
2.Connect to the DO(BRW+/BRW-)
4.1.6 Servo Running
1. Enable servo driver
Check if CN3/CN4 is connected properly. Servo driver is in ready mode. Motor is stopped
and holding brake is activated. Front panel display shows 402 state machine =
Operational, EtherCAT communication status = operational, Running mode = 8, servo is in
stop mode.