Pr6.63
Label
Absolute multiturn data
upper limit
Mode
F
Range
0~32766
Unit
rev
Default
0
Index
2663h
Activation
After restart
To set upper limit of multiturn data with absolute encoder set as rotational mode.
When Pr0.15 = 2 and use in combination with Pr6.54:
Feedback load position 6064=
54
.
6
PA
63
.
6
PA
x Electronic gear ratio
3.2.8
【
Class 7
】
Factory settings
Please take precaution when modifying Class 7 parameters. Might cause driver errors
Pr7.15
Label
Motor model
Mode
F
Range
0x0~0x7FF
F
Unit
-
Default
0x200
Property
R/W
Activation
After restart
Data length
16 bit
Set value
Description
0x100
Read from EEPROM
[0x200]
Read from Encoder
When Pr7.15 = 0x200(2xx):
Parameter
Label
Pr7.00
Current loop gain
Pr7.01
Current loop integral time
Pr7.05
No. of motor pole pairs
Pr7.06
Motor phase resistance
Pr7.07
Motor D/Q induction
Pr7.08
Motor back EMF coefficient
Pr7.09
Motor torque coefficient
Pr7.10
Motor rated rotational speed
Pr7.11
Motor max. rotational speed
Pr7.12
Motor rated current
Pr7.13
Motor rotor inertia
Pr7.14
Driver power rating
Pr7.16
Encoder
Pr7.17
Motor max. current
Pr7.18
Encoder index angle compensation
Pr7.16
Label
Encoder
Mode
F
Range
0x0~0x200
Unit
-
Default
As per
encoder
Property
R/W
Activation
After restart
Data length
16 bit
Set value
Description
0x0
17-bit encoder
0x7