User manual of EL8-EC***F AC Servo
113
Pr5.45
Label
External
encoder overspeed
feedback threshold
Mode
F
Range
0~10000
Unit
rpm
Default
0
Index
2545h
Activation
Immediate
To set external encoder overspeed feedback threshold
Pr5.46
Label
Vent overload level
Mode
F
Range
0~115
Unit
%
Default
0
Index
2546h
Activation
Immediate
Set value
Description
【
0
】
Default level: 80%
1~115
Set vent overload level accordingly
Pr5.70
Label
Enable position comparison
Mode
F
Range
0~1
Unit
%
Default
0
Index
2570h
Activation
Immediate
Set Value
Description
【
0
】
Disable
1
Enable
(
Rising edge
)
Pr5.71
Label
Position comparison mode
Mode
F
Range
0~2
Unit
-
Default
0
Index
2571h
Activation
Immediate
Set value
Description
【
0
】
Single comparison
1
N cycles comparison
2
Cycle comparison
Detailed explanations is available in Chapter 6 Application under Position Comparison section
Pr5.72
Label
Position comparison pulse output
width
Mode
F
Range
0~4095
Unit
ms
Default
0.1ms
Index
2572h
Activation
Immediate
To set output signal pulse width of position comparison