User manual of EL8-EC***F AC Servo
68
60B8
0
Probe function
-
0x0
0x0
0xFFFF
F
60B9
0
Probe status
-
0x0
0x0
0xFFFF
F
60BA
0
Probe 1 rising edge
captured position
Comman
d unit
0
-21474
83648
214748
3647
F
60BB
0
Probe 1 falling edge
captured position
Comman
d unit
0
-21474
83648
214748
3647
F
60BC
0
Probe 2 rising edge
captured position
Comman
d unit
0
-21474
83648
214748
3647
F
60BD
0
Probe 2 falling edge
captured position
Comman
d unit
0
-21474
83648
214748
3647
F
60C5
0
Protocol maximum
acceleration
Comman
d unit /
s²
10000
0000
1
214748
3647
F
60C6
0
Protocol maximum
deceleration
Comman
d unit /
s²
10000
0000
1
214748
3647
F
60D5
0
Probe 1 rising edge
captured count(s)
-
0
0
65535
F
60D6
0
Probe 1 falling edge
captured count(s)
-
0
0
65535
F
60D7
0
Probe 2 rising edge
captured count(s)
-
0
0
65535
F
60D8
0
Probe 2 falling edge
captured count(s)
-
0
0
65535
F
60E0
0
Max. torque in positive
direction
0.001
3000
0
65535
F
60E1
0
Max. torque in negative
direction
0.001
3000
0
65535
F
60F4
0
Actual following error
Comman
d unit
0
-21474
83648
214748
3647
CSP/P
P/HM
60FA
0
Position loop velocity output
Comman
d unit /s
0
-21474
83648
214748
3647
CSP/P
P/HM
60FC
0
Internal command position
Encoder
unit
0
-21474
83648
214748
3647
CSP/P
P/HM
60FD
0
Input status
-
0x0
0x0
0x7FFF
FFFF
F
60FE
1
Output valid
-
0x0
0x0
0x7FFF
FFFF
F
2
Output enabled
-
0x0
0x0
0x7FFF
FFFF
F
60FF
0
Target velocity
Comman
d unit /s
0
-21474
83648
214748
3647
CSV/P
V
6502
0
Supported operation modes
-
0x0
0x0
0x7FFF
FFFF
F