User manual of EL8-EC***F AC Servo
176
AF Enc Motor angle correction
Auxiliary function
AF Enc
Operation
Enc -
Initialization
S
StArt
FinSh
Completed
Motor angle
correction
Press
▲
once to start correct(displays
StArt)
FinSh is displayed once completed.
Start correction
AF_GL Inertia measuring
Please make sure: 1. Velocity < 300RPM, average velocity duration < 50ms
2. Acceleration/Deceleration time < 500ms
Press
S
to exit and disable the driver once completed.
Auxiliary function
AF_GL
Inertia
measuring
Operation
G -----
Initialization
S
SrUon
Error
P 400
n 400
CCW
▲
▼
CW
G 200
Press
◀
to start inertia measuring.
S
rUon will be displayed.
If driver is
enabled before
◀
is pressed, error
might occur.
Hold
▲
or
▼
to
move motor in
CW/CCW direction
to measure
inertia.
G xxx will be displayed on completed. xxx
is the inertia value from the measurement.
Hold M to save the value to Pr0.04.