User manual of EL8-EC***F AC Servo
43
2.13 Analog and Z-phase open collector output CN8
CN8 has 2 analog outputs and 1 Z-phase open collector output
Analog outputs
Both analog outputs settings can be modified in Pr4.65 and Pr4.70.
AO1
1
Analog output 1
Analog output 2
C
N
8
GND
2
AO2
3
GND
4
Encoder Z-phase crossover frequency output (Open Collector)
Encoder output signal will be through Open Collector after frequency division. Please
connect ground terminal of external power supply to CN6 pin 6 signal ground using double
winding shielded cable for better protection against interference.
OCZ
GND
5
6
External
0V
Driver
External
5V~24V
U
ps
tre
am
de
vic
e
CN8
Port
Diagram
Pin
Signal
Description
Remarks
CN8
5
6
1
2
1
AO1
Analog output 1
2
GND
Signal ground
3
AO2
Analog output 2
4
GND
Signal ground
5
OCZ
Z-Phase open
collector output
Only NPN Open
collector output
6
GND
Signal ground