User manual of EL8-EC***F AC Servo
281
(
2
)
Continuous trigger mode
The data saved from signal triggering will be saved until the next trigger signal.
Enabling the probe again is not needed. Sequence diagram as shown below:
6.18 Safety Functions
6.18.1 External brake deactivation output signal BRW-OFF
Please refer to Pr4.11 to set up the I/O output function parameters. When enabled and
timing conditions are fulfilled, the set I/O output will deliver ON signal.
Pr4.37
Name
Motor power-off delay time
Mode
F
Range
0~3000
Unit
1ms
Default
100
Index
2437h
Activation
Immediate
To set delay time for holding brake to be activated after motor power off to prevent axis from
sliding.
Pr4.38
Name
Delay time for holding brake
release
Mode
F
Range
0~3000
Unit
1ms
Default
0
Index
2438h
Activation
Immediate
To set delay time for holding brake to be released after motor power on. Motor will
remain at current position and input command is masked to allow holding brake to be
fully released before motor is set in motion.