User manual of EL8-EC***F AC Servo
85
Pr1.18
Label
Hysteresis at position
control switching
Mode
F
Range
0~2000
0
Unit
Mode
dependent
Default
33
Index
2118h
Activation
Immediate
To eliminate the instability of gain switching. Used in combination with Pr1.17 using the same unit.
If level< hysteresis, drive will set internally hysteresis = level.
Pr1.19
Label
Position gain switching
time
Mode
F
Range
0~1000
0
Unit
0.1ms Default
33
Index
2119h
Activation
Immediate
During position control, to ease torque changes and vibration due to rapid changes in position
loop gain, set suitable Pr1.19 value
For example: 1
st
(pr1.00) <-> 2nd (Pr1.05)
Pr1.36
Label
External ABZ encoder filter
time
Mode
PP
CS
P
Range
0~300
Unit
0.01us Default
20
Index
2136h
Activation
Immediate
To set filter time for external ABZ encoder
Pr1.39
Label
Special function registry 2
Mode
F
Range
0-0xFFF
F
Unit
0.01us Default
0
Index
2139h
Activation
Immediate
Set value
Description
【
0
】
Reserved
1
=1, activate full closed loop during trial run
2
=1, hybrid position deviation clearing