User manual of EL8-EC***F AC Servo
132
gone
Direction
Deceleration point
Home
Before Z-signal
1
Negative
Negative limit switch Motor Z-signal
Negative limit switch falling edge
2
Positive
Positive limit switch
Motor Z-signal
Positive limit switch falling edge
3
Positive
Homing switch
Motor Z-signal
Falling edge on same side of
homing switch
4
Positive
Homing switch
Motor Z-signal
Rising edge on same side of
homing switch
5
Negative
Homing switch
Motor Z-signal
Falling edge on same side of
homing switch
6
Negative
Homing switch
Motor Z-signal
Rising edge on same side of
homing switch
7
Positive
Homing switch
Motor Z-signal
Falling edge on same side of
homing switch
8
Positive
Homing switch
Motor Z-signal
Rising edge on same side of
homing switch
9
Positive
Homing switch
Motor Z-signal
Rising edge on same side of
homing switch
10
Positive
Homing switch
Motor Z-signal
Falling edge on same side of
homing switch
11
Negative
Homing switch
Motor Z-signal
Failling edge on same side of
homing switch
12
Negative
Homing switch
Motor Z-signal
Rising edge on same side of
homing switch
13
Negative
Homing switch
Motor Z-signal on
other side of
homing switch
Rising edge on other side of
homing switch
14
Negative
Homing switch
Motor Z-signal on
other side of
homing switch
Falling edge on other side of
homing switch
15
16
17-32
Similar with 1-14, but deceleration point = homing point
33
Home in negative direction, Homing point = motor Z-signal
34
Home in positive direction, Homing point = motor Z-signal
35-37
Set current position as homing point
Index
6099h-0
1
Label
High speed homing
Unit
Command
unit/s
Structure
VAR
Type
UInt 32
Access
R
W
Mappin
g
RPD
O
Mode
HM
Range
0~214
74836
47
Default
10000
To set the speed used in homing
Index
6099h-0
2
Label
Low speed homing
Unit
Command
unit/s
Structure
VAR
Type
UInt 32
Access
R
W
Mappin
g
RPD
O
Mode
HM
Range
0~214
74836
47
Default
5000
To set the speed used in homing