User manual of EL8-EC***F AC Servo
123
2
:
Motor decelerates and stops through 6085h. Status: Switch on disable, axis disabled.
3
:
Motor decelerates and stops through 60C6h. Status: Switch on disable, axis disabled.
5
:
Motor decelerates and stops through 6084h. Status: Quick stop
6
:
Motor decelerates and stops through 6085h. Status: Quick stop
7
:
Motor decelerates and stops through 60C6h. Status: Quick stop
HM
0
:
To stop motor through Pr5.06. Status: Switch on disable, axis disabled.
1
:
Motor decelerates and stops through 609Ah. Status: Switch on disable, axis disabled.
2
:
Motor decelerates and stops through 6085h. Status: Switch on disable, axis disabled.
3
:
Motor decelerates and stops through 60C6h. Status: Switch on disable, axis disabled.
5
:
Motor decelerates and stops through 609Ah. Status: Quick stop
6
:
Motor decelerates and stops through 6085h. Status: Quick stop
7
:
Motor decelerates and stops through 60C6h. Status: Quick stop
CST
0
:
To stop motor through Pr5.06. Status: Switch on disable, axis disabled.
1, 2
:
Motor decelerates and stops through 6087h. Status: Switch on disable, axis disabled.
3
:
Motor decelerates and stops through torque = 0. Status: Switch on disable, axis disabled.
5, 6
:
Motor decelerates and stops through 6087h. Status: Quick stop
7
:
Motor decelerates and stops through torque = 0. Status: Quick stop
Index
605Bh
Label
Motor deceleration-stopping
mode selection
Mode
F
Range
RW
Unit
-
Range
0~1
Default
0
PP, CSP, CSV, PV
0
:
To stop motor through Pr5.06, Pr5.06 = 0(Emergency stop), Pr5.06=1(Free stop)
1
:
Motor decelerates and stops through 6084h
HM
0
:
To stop motor through Pr5.06, Pr5.06 = 0(Emergency stop), Pr5.06=1(Free stop)
1
:
Motor decelerates and stops through 609Ah
CST
0
:
To stop motor through Pr5.06, Pr5.06 = 0(Emergency stop), Pr5.06=1(Free stop)
1
:
Motor decelerates and stops through 6087h
Index
605Ch
Label
Axis disabled-stopping mode
selection
Mode
F
Range
RW
Unit
-
Range
0~1
Default
0
PP, CSP, CSV, PV
0
:
To stop motor through Pr5.06, Pr5.06 = 0(Emergency stop), Pr5.06=1(Free stop)
1
:
Motor decelerates and stops through 6084h
HM
0
:
To stop motor through Pr5.06, Pr5.06 = 0(Emergency stop), Pr5.06=1(Free stop)