User manual of EL8-EC***F AC Servo
56
2.11.2 Using line filter
To reduce interference from main power supply cable and to prevent from affecting other
sensitive components around the servo drive, please choose a line filter based on actual
supply current. Please do be aware of the following mistake when installing a line filter.
Do not band the main power supply cable together.
Contactor
Line
Filter
Contactor
Line
filter
AC
P
ow
er
S
uppl
y
Wrong
Correct
L1
L2
L3
AC
P
ow
er
S
uppl
y
Separate the ground wire from the line filter and the main power supply cable.
Line
Filter
Wrong
Correct
L1
L2
L3
Contactor
Line
Filter
AC
P
ow
er
S
uppl
y
L1
L2
L3
AC
P
ow
er
S
uppl
y
Contactor
Ground wires inside an electrical cabinet
Contactor
Line
Filter
L1
L2
L3
Servo
drive
Servo
drive
Shield grounding
Ground
AC
Pow
er
S
uppl
y