Keysight N9923-90001 User’s Guide 139
Frequency Offset Using Power Sensor (FOPS) – Option 208
FOPS Settings
FOPS Settings
The following settings are unique to FOPS. Standard USB Power Meter mode
settings, which may be useful with FOPS, are documented in that chapter
starting in
“USB Power Meter Settings” on page 128
Select Power Meter (USB Sensor) before making any setting in this section.
How to select Power Meter (USB Sensor)
— Press
Mode
— Then
Power Meter (USB Sensor)
— Then connect a USB Power Sensor to either FieldFox USB port.
— For a complete list of supported Keysight USB Power Sensors, please visit:
www.keysight.com/find/usbsensorsforfieldfox
Measurement Selection
— Press
Measure 1
— Then choose from the following:
—
Src Power Measure
Similar to a ‘normalization’ cal, this selection guides
you through the following steps to make a measurement at the reference
plane and then store the data trace into memory.
1. Connect the power sensor to the measurement reference plane. This
is the location to where power measurements are to be referenced.
For example, to measure only the conversion loss through a
converter, attach the power sensor to the cable that connects to the
converter input.
2. Press
Measure
. When finished, press
Src Data -> Mem
to store the
measured data into FieldFox memory. Preset or Mode Preset will
clear the stored memory.
3. Optionally choose from the following:
—
Re-Measure
Make another measurement
—
Src Data
View only the re-measured data.
—
Src Memory
View only the stored memory data.
—
Src Data & Memory
View both the re-measured data and
the stored memory data.
4. Press
Done
—
Src Power Memory
Not available until source data is stored into memory.
Displays only the source power memory trace.
Summary of Contents for N9923A
Page 1: ...Keysight Technologies FieldFox RF Network Analyzers N9923A User s Guide ...
Page 14: ...14 Keysight N9923 90001 User s Guide Contents ...
Page 20: ...20 Keysight N9923 90001 User s Guide Overview FieldFox Manuals Software and Supplemental Help ...
Page 60: ...60 Keysight N9923 90001 User s Guide NA Network Analyzer Mode NA Mode Settings ...
Page 134: ...134 Keysight N9923 90001 User s Guide Power Meter USB Mode USB Power Meter Settings ...
Page 206: ...206 Keysight N9923 90001 User s Guide File Management Printing ...
Page 264: ...264 Keysight N9923 90001 User s Guide Specifications Data Sheet ...
Page 267: ...267 Keysight N9923A Handheld Analyzer User s Guide D Korean Battery Safety Translation ...
Page 268: ...268 Keysight N9923 90001 User s Guide Korean Battery Safety Translation ...
Page 269: ...Keysight N9923 90001 User s Guide 269 Korean Battery Safety Translation ...
Page 270: ...270 Keysight N9923 90001 User s Guide Korean Battery Safety Translation ...
Page 275: ...Installation Note Xxxxx xxxxx 3 ...