System Settings
Audio (Volume) Control
—
Preset (User)
The entire UserPreset.sta file is recalled. ALL modes
assume the settings that were in place when the User Preset was
saved. The active mode is the mode that was visible when the file was
saved.
—
Mode Preset (User)
The settings for only the current mode are recalled
from UserPreset.sta.
Audio (Volume) Control
System volume control is a FieldFox global setting which sets speaker volume
for ALL success beeps, key press clicks, and individual features that use the
FieldFox speaker, such as SA Mode Tune and Listen.
The volume control setting remains through a FieldFox Preset. To cause your
volume control setting to remain through a FieldFox shut down, save the
setting as a Preference. Learn how in
“Save and Reset Preferences” on
.
How to set FieldFox Volume Control
— Press
System 7
— Then
Volume
— Then use the
arrows, the rotary knob, or numeric keypad to enter a
value between 0 (lowest volume) and 100 (highest volume).
— Press
Volume
again and select Mute to quickly turn OFF the speaker
volume.
— Press
Volume
again to set volume ON to the previous volume control.
—
Only the instrument settings are saved to UserPreset.sta. No trace data
or calibration data is saved.
—
User Preset ON / OFF is saved as a Preference setting. Like all
preferences, this setting survives a FieldFox shut down and power ON.
Therefore, when User Preset is ON during shut down, the FieldFox will
load UserPreset.sta when it is powered ON.
—
To return to Factory Preset, select
User Preset OFF
. The contents of
UserPreset.sta remain stored on the FieldFox. When User Preset is OFF,
you can also set the Startup Mode preference that determines which
mode will be visible after powering ON. Learn more in
.
Summary of Contents for N9923A
Page 1: ...Keysight Technologies FieldFox RF Network Analyzers N9923A User s Guide ...
Page 14: ...14 Keysight N9923 90001 User s Guide Contents ...
Page 20: ...20 Keysight N9923 90001 User s Guide Overview FieldFox Manuals Software and Supplemental Help ...
Page 60: ...60 Keysight N9923 90001 User s Guide NA Network Analyzer Mode NA Mode Settings ...
Page 134: ...134 Keysight N9923 90001 User s Guide Power Meter USB Mode USB Power Meter Settings ...
Page 206: ...206 Keysight N9923 90001 User s Guide File Management Printing ...
Page 264: ...264 Keysight N9923 90001 User s Guide Specifications Data Sheet ...
Page 267: ...267 Keysight N9923A Handheld Analyzer User s Guide D Korean Battery Safety Translation ...
Page 268: ...268 Keysight N9923 90001 User s Guide Korean Battery Safety Translation ...
Page 269: ...Keysight N9923 90001 User s Guide 269 Korean Battery Safety Translation ...
Page 270: ...270 Keysight N9923 90001 User s Guide Korean Battery Safety Translation ...
Page 275: ...Installation Note Xxxxx xxxxx 3 ...