NA (Network Analyzer) Mode
NA Mode Settings
All FieldFox settings and features are supported (except Parameter Conversion)
with mixed-mode S-parameters.
How to make mixed-mode S-parameter measurements
— Press
Measure 1
.
— Then
More
.
— Then choose from the following:
—
Scc11
Common reflect/common incident for logical port 1.
—
Sdd11
Differential reflect/differential incident for logical port 1.
—
Sdc11
Differential reflect/common incident for logical port 1.
—
Scd11
Common reflect/differential incident for logical port 1.
To make balanced reflection measurements at the DUT output, connect the
DUT output to the FieldFox ports.
Parameter Conversion
In NA Mode ONLY, converts the active S-parameter trace to an equivalent
impedance (Z), admittance (Y), or reciprocal 1/S-parameter
How to select parameter conversions
— Press
Measure 1
— Then select an S-parameter
— Then
More
— Then
Conversion
— Then choose from the following:
—
Off
(default) No conversion is performed.
—
Z Conv (--) or Y Conv (--)
Perform conversion for impedance (Z) or
admittance (Y). Then choose from the following for either:
——
Auto
The displayed S-parameter is converted to the
appropriate Z or Y parameter: Refl for S11 and S22; Trans for
S21 and S12. When the S-parameter is changed, the
appropriate conversion changes automatically.
——
Refl
The displayed S-parameter is converted to Z or Y
reflection, regardless of whether the S-parameter is reflection
(S11 or S22) or transmission (S21 or S12).
Learn more about Balanced Measurements with the FieldFox in the
FieldFox Supplemental Online Help:
http://na.support.keysight.com/fieldfox/help/SupHelp/FieldFox.htm
Summary of Contents for N9923A
Page 1: ...Keysight Technologies FieldFox RF Network Analyzers N9923A User s Guide ...
Page 14: ...14 Keysight N9923 90001 User s Guide Contents ...
Page 20: ...20 Keysight N9923 90001 User s Guide Overview FieldFox Manuals Software and Supplemental Help ...
Page 60: ...60 Keysight N9923 90001 User s Guide NA Network Analyzer Mode NA Mode Settings ...
Page 134: ...134 Keysight N9923 90001 User s Guide Power Meter USB Mode USB Power Meter Settings ...
Page 206: ...206 Keysight N9923 90001 User s Guide File Management Printing ...
Page 264: ...264 Keysight N9923 90001 User s Guide Specifications Data Sheet ...
Page 267: ...267 Keysight N9923A Handheld Analyzer User s Guide D Korean Battery Safety Translation ...
Page 268: ...268 Keysight N9923 90001 User s Guide Korean Battery Safety Translation ...
Page 269: ...Keysight N9923 90001 User s Guide 269 Korean Battery Safety Translation ...
Page 270: ...270 Keysight N9923 90001 User s Guide Korean Battery Safety Translation ...
Page 275: ...Installation Note Xxxxx xxxxx 3 ...