CAT (Cable and Antenna Test) Mode
CAT Mode Settings
—
Left
The Settings table is shown to the left of the trace window
—
Bottom
The Settings table is shown below the trace window
— When finished changing ALL settings, press
Done
to save your settings
Frequency Range
Set the range of frequencies over which you would like to make CAT Mode
measurements
When the frequency range is changed after a calibration is performed, the cal
becomes interpolated. Learn more in
.
How to set Frequency Range
— Press
Freq/Dist
.
— Then choose from the following
—
Start
and
Stop
frequencies - beginning and end of the sweep.
—
Center
and
Span
frequencies – the center frequency and span of
frequencies (half on either side of center).
— Follow each setting by entering a value using the numeric keypad,
arrows, or the rotary knob.
—After using the keypad, select a multiplier key. Learn about multiplier
abbreviations in
“Multiplier Abbreviations” on page 34
—After using the
arrows or the rotary knob, press
Enter
. The
amount of frequency increment is based on the current span and can
NOT be changed in CAT Mode.
Scale Settings
Adjust the Y-axis scale to see the relevant portions of the data trace. The Y-axis
is divided into 10 graticules.
This setting can be changed at any time without affecting calibration accuracy.
How to set Scale
— Press
Scale / Amptd
.
— Then choose from the following three methods:
1.
Autoscale All
Autoscales all of the traces on the screen, useful only
for dual-trace configurations.
2. Set Scale, Reference Level, and Reference Position:
—
Scale
Manually enter a
scale per division
to view specific
areas of the trace
Summary of Contents for N9923A
Page 1: ...Keysight Technologies FieldFox RF Network Analyzers N9923A User s Guide ...
Page 14: ...14 Keysight N9923 90001 User s Guide Contents ...
Page 20: ...20 Keysight N9923 90001 User s Guide Overview FieldFox Manuals Software and Supplemental Help ...
Page 60: ...60 Keysight N9923 90001 User s Guide NA Network Analyzer Mode NA Mode Settings ...
Page 134: ...134 Keysight N9923 90001 User s Guide Power Meter USB Mode USB Power Meter Settings ...
Page 206: ...206 Keysight N9923 90001 User s Guide File Management Printing ...
Page 264: ...264 Keysight N9923 90001 User s Guide Specifications Data Sheet ...
Page 267: ...267 Keysight N9923A Handheld Analyzer User s Guide D Korean Battery Safety Translation ...
Page 268: ...268 Keysight N9923 90001 User s Guide Korean Battery Safety Translation ...
Page 269: ...Keysight N9923 90001 User s Guide 269 Korean Battery Safety Translation ...
Page 270: ...270 Keysight N9923 90001 User s Guide Korean Battery Safety Translation ...
Page 275: ...Installation Note Xxxxx xxxxx 3 ...