112 Keysight N9923-90001 User’s Guide
Calibration for NA, CAT, and VVM Modes
—
OFF
If power to the ECal module is too low, it cannot detect which
FieldFox ports it is connected to. If you are having this problem,
select OFF. Then during the calibration, the FieldFox will prompt you
to connect the ECal module ports to specific FieldFox ports.
— Optionally press
Advanced
then
Simple ECal
.
—
ON
(default) The FieldFox assumes that both ports of the ECal module
can be connected at both calibration reference planes. You therefore
receive a single prompt to connect the ECal module to both ports.
—
OFF
Select when physical restrictions prohibit the ECal module from
being connected to both calibration reference planes simultaneously.
You will receive separate prompts to connect the ECal module to Port
1, then to connect the ECal to Port 2.
— Press
Start Calibration
. When prompted, verify the ECal module
connection, then press Measure. The standards within the ECal module are
automatically connected and measured.
Simple Response Cals
Simple Response Cals are used to quickly calibrate the magnitude and phase
of a measurement using any Open, Short, or Thru component. These may be
calibration standards, but because a Cal Kit is not selected, they are not
modeled. Measurement accuracy is generally low. Use a Simple Response Cal
to make quick measurements when using a jumper cable to connect the DUT
to the FieldFox. Otherwise, CalReady is usually more accurate.
When prompted, choose a standard based on the displayed measurements to
be calibrated. For example, to calibrate S11, connect either an OPEN or
SHORT to the port 1 reference plane.
When Simple Response Cals are performed, the source match and reflection
tracking terms from CalReady are updated by the measured Short or Open that
is used during the calibration.
1-port response cals are also available from the Mechanical Cal menu. Learn
more in
“Calibration Type” on page 114
When prompted:
“Connect port 1 to port 2"
,
then you can connect them
however you choose, including using the internal ECal THRU. This is an
‘Unknown THRU’.When prompted:
“Connect port 1 directly to port 2"
,
then
you must connect the ports directly together at the calibration reference
plane with no adapter or other cabling. This is a ‘Flush THRU’. Learn more
in
“Calibration Type” on page 114
.
You can perform a Simple Response Cal for either: S11, or S22, or S21 AND
S12.
Summary of Contents for N9923A
Page 1: ...Keysight Technologies FieldFox RF Network Analyzers N9923A User s Guide ...
Page 14: ...14 Keysight N9923 90001 User s Guide Contents ...
Page 20: ...20 Keysight N9923 90001 User s Guide Overview FieldFox Manuals Software and Supplemental Help ...
Page 60: ...60 Keysight N9923 90001 User s Guide NA Network Analyzer Mode NA Mode Settings ...
Page 134: ...134 Keysight N9923 90001 User s Guide Power Meter USB Mode USB Power Meter Settings ...
Page 206: ...206 Keysight N9923 90001 User s Guide File Management Printing ...
Page 264: ...264 Keysight N9923 90001 User s Guide Specifications Data Sheet ...
Page 267: ...267 Keysight N9923A Handheld Analyzer User s Guide D Korean Battery Safety Translation ...
Page 268: ...268 Keysight N9923 90001 User s Guide Korean Battery Safety Translation ...
Page 269: ...Keysight N9923 90001 User s Guide 269 Korean Battery Safety Translation ...
Page 270: ...270 Keysight N9923 90001 User s Guide Korean Battery Safety Translation ...
Page 275: ...Installation Note Xxxxx xxxxx 3 ...