VVM (Vector Voltmeter) Mode - Option 308
VVM Mode Settings
— Then
More
— Then
Output Power
—
High
(Default setting) Sets output power to the maximum achievable
power at all displayed frequency. Please see the FieldFox
Specifications for expected power levels
—
Low
Sets output power to approximately –42 dBm.
—
Man
Set output power to an arbitrary value.
— Then press
Nominal Power
— Then enter a value using the numeric keypad, the
arrows, or the
rotary knob.
— Press
Enter
.
Averaging
Averaging helps to reduce the effects of random noise on a measurement. The
FieldFox computes the displayed value over several consecutive readings.
Average count determines the number of readings to average. The higher the
average count, the greater the amount of noise reduction.
An average counter is shown in the left edge of the screen as
Avg N
. This
shows the number of previous readings that have been averaged together.
When the counter reaches the specified count, then a ‘running average’ of the
last
N
readings is displayed.
Average count = 1 means there is NO averaging.
This setting can be changed at any time without affecting calibration accuracy.
How to set Averaging
— Press
Meas Setup 4
— Then
More
— Then
Avg N
where
N
is the current count setting.
— Enter a value using the numeric keypad. Enter
1
for NO averaging.
— Press
Enter
.
To restart the averaging process, press
Meas Setup 4
, then
More
, then
Restart
Single or Continuous Measure
This setting determines whether the FieldFox measures continuously or only
once each time the
Single
button is pressed. Use
Single
to conserve battery
power or to allow you to save or analyze a specific measurement.
Summary of Contents for N9923A
Page 1: ...Keysight Technologies FieldFox RF Network Analyzers N9923A User s Guide ...
Page 14: ...14 Keysight N9923 90001 User s Guide Contents ...
Page 20: ...20 Keysight N9923 90001 User s Guide Overview FieldFox Manuals Software and Supplemental Help ...
Page 60: ...60 Keysight N9923 90001 User s Guide NA Network Analyzer Mode NA Mode Settings ...
Page 134: ...134 Keysight N9923 90001 User s Guide Power Meter USB Mode USB Power Meter Settings ...
Page 206: ...206 Keysight N9923 90001 User s Guide File Management Printing ...
Page 264: ...264 Keysight N9923 90001 User s Guide Specifications Data Sheet ...
Page 267: ...267 Keysight N9923A Handheld Analyzer User s Guide D Korean Battery Safety Translation ...
Page 268: ...268 Keysight N9923 90001 User s Guide Korean Battery Safety Translation ...
Page 269: ...Keysight N9923 90001 User s Guide 269 Korean Battery Safety Translation ...
Page 270: ...270 Keysight N9923 90001 User s Guide Korean Battery Safety Translation ...
Page 275: ...Installation Note Xxxxx xxxxx 3 ...