PS220 Configuration & Operation Guide
PS220 48
Process
Control
1. Configure the sleep Mode.
The choices are:
1. Off. Disable the Sleep function.
1. “ARROW RIGHT” to change
2. “ARROWS UP/DOWN” to change value
3. “Save”
2. Min Speed is the default setting. When set properly the drive will sleep as described above. With this choice
the pump will sleep when the 3 values of “Sleep Value”, “Minimum Speed”, and the “Sleep Delay” have all been
achieved. A Dead Head test is strongly recommended to be performed to correctly set the minimum speed. Refer
to Dead Head in this manual.
Note: If using “Minimum Speed” for use in the “Alarm & Control Pump Protection Response” Min Speed Sleep is
not an available choice. See “Intelligent Sleep”
Additional Wizards will need to be run when configuring the Intelligent Sleep selection to function correctly:
1. SmartFlow Wizard if being used for this value for flow.
2. Pump & VFD Protection Wizard, if an external flowmeter is used that is not the primary process control
transmitter selected previously.
2. Configure the Sleep Value
1. “ARROW RIGHT” to change
2. “ARROWS” to change value
3. “Save”
4. “ARROW DOWN”
Summary of Contents for PumpSmart PS220
Page 1: ...Configuration Operation Manual PumpSmart Control Solutions PS220 v6 05...
Page 22: ...PS220 Configuration Operation Guide 21 PS220 SmartFlow...
Page 261: ...PS220 Configuration Operation Guide PS220 260 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 283: ...PS220 Configuration Operation Guide PS220 282 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 289: ...PS220 Configuration Operation Guide PS220 288 Ecodesign Regulation...
Page 292: ...PS220 Configuration Operation Guide 291 PS220 Fuses heat dissipation chart...