TimeForce II Hardware Guide
185
Installing an External Door Security Reader
Installing an External Door
Security Reader
Introduction
The Door Security feature of an Infinisource time clock allows you to
connect the clock relay to an external door switch (or, Wiegand reader).
When an employee’s punch at the time clock is accepted, the relay acti-
vates and the door opens.
External Wiegand readers (either Infinisource or HID) connect to the
clock via a 3 or 4 contact screw terminal. There may be either 3 or 4
wires used from the external reader, depending on the version of your
time clock motherboard.
Wires of any other color should be trimmed so that no bare wire shows,
and then taped or tie-wrapped so that they do not contact any other wire
or metal, such as conduit or door frames.
Table HARDWARE-3: Wiegand Contacts
Signal
Wire Color
Description
Data1
White
Data from reader to clock
Data0
Green
Data from reader to clock
Ground
Black/Bare
Shield Wire
Power and data ground
VCC
Red
Power (not present on earlier board versions)