Installing a Bell/Buzzer
3.
Loosen both screws on the top of the relay connection.
NOTE:
Make sure that the electrical wires are not live. Serious
injury or death can result from coming in contact with live electri-
cal wires.
4.
Locate the three bell wires. One is the ground wire, one is the
power source positive wire, and one is the power source negative
wire.
5.
Connect the power source ground wire to the ground terminal on
the bell.
6.
Connect the power source negative wire to the negative terminal on
the bell.
7.
Connect the power source positive wire to the positive terminal on
the bell.
8.
Measure an appropriate distance down the power source positive
wire from the bell and cut the wire (the distance between the bell
and the place where you cut the positive wire determines how far
the bell can be from the clock).
Make sure you cut
only
the positive
wire
.
9.
Strip 1/4 inch of insulation from each of the two positive wire ends
created in step 8 and insert one exposed wire into each of the two
holes on the relay connector. See Figure HARDWARE-4.