Important:
If there is a gap between the DIMM and the retaining clips, the DIMM is not correctly
installed. Open the retaining clips to remove and reinsert the DIMM. Install a DIMM filler (C) in any
location where a DIMM is not present to avoid machine damage.
11.
Install and close the compute node cover. See “Installing and closing the compute node cover” on
page 41.
Statement 21
CAUTION:
Hazardous energy is present when the compute node is connected to the power source. Always
replace the compute node cover before installing the compute node.
12.
Install the compute node into the IBM Flex System Enterprise Chassis. See “Installing the compute
node in an IBM Flex System Enterprise Chassis” on page 93.
13.
If you replaced the part because of a service action, verify the repair by checking that the amber
enclosure fault LED is off. For more information, see “Compute node control panel button and
LEDs” on page 11.
Related concepts
:
“Supported DIMMs”
Your compute node contains connectors for registered dual inline memory modules (RDIMMs).
Supported DIMMs
Your compute node contains connectors for registered dual inline memory modules (RDIMMs).
Each system board in the IBM Flex System p260 Compute Node contains connectors for 16 low profile
(LP) or very low profile (VLP) memory DIMMs. The IBM Flex System p460 Compute Node supports up
to 32 DIMMs.
The maximum size for a single DIMM is 8 GB for a VLP DIMM and 32 GB for an LP DIMM. The
maximum memory capacity for an IBM Flex System p260 Compute Node is 512 GB and for an IBM Flex
System p460 Compute Node is 1024 GB.
Memory module rules:
v
Install DIMM fillers in unused DIMM slots for proper cooling.
v
Install DIMMs in pairs (1 and 4, 5 and 8, 9 and 12, 13 and 16, 2 and 3, 6 and 7, 10 and 11, and 14 and
15).
v
Both DIMMs in a pair must be the same size, speed, type, and technology. You can mix compatible
DIMMs from different manufacturers.
v
Each DIMM within a processor-support group (1-4, 5-8, 9-12, 13-16) must be the same size and speed.
v
Install only supported DIMMs, as described on the ServerProven website.
v
Installing or removing DIMMs changes the configuration of the compute node. After you install or
remove a DIMM, the compute node is automatically reconfigured, and the new configuration
information is stored.
The following table shows allowable placements of DIMM modules for the IBM Flex System p260
Compute Node. Table 7 on page 60 shows allowable placements of DIMM modules for the IBM Flex
System p460 Compute Node.
Chapter 6. Installing and removing components
59
Summary of Contents for P260
Page 1: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Page 2: ......
Page 3: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Page 32: ...20 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 44: ...32 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 46: ...34 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 108: ...96 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 116: ...104 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 512: ...500 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 523: ...Appendix Notices 511 ...
Page 524: ...IBM Printed in USA ...