AAxxyyyy partition firmware attention codes:
AAxxyyyy attention codes provide information about the next target state for the platform firmware.
These codes might indicate that you need to perform an action.
The AAxxyyyy SRCs below are the partition firmware codes that might be displayed if the POST detects
a problem. Follow the suggested actions in the order in which they are listed until the problem is solved.
If an action solves the problem, then you can stop performing the remaining actions. See Chapter 7,
“Parts listing for IBM Flex System p260 and p460 Compute Nodes,” on page 97 to determine which
components are CRUs and which components are FRUs.
AA00E1A8
Explanation:
The system is booting to the open firmware prompt.
Response:
At the open firmware prompt, type dev /packages/gui obe and press Enter; then, type 1 to select SMS
Menu.
AA00E1A9
Explanation:
The system is booting to the System Management Services (SMS) menus.
Response:
1.
If the system or partition returns to the SMS menus after a boot attempt failed, use the SMS menus to check the
progress indicator history for a BAxx xxxx error, which may indicate why the boot attempt failed. Follow the
actions for that error code to resolve the boot problem.
2.
Use the SMS menus to establish the boot list and restart the server.
AA00E1B0
Explanation:
Waiting for the user to select the language and keyboard. The menu should be visible on the console.
Response:
1.
Check for server firmware updates.
2.
Apply any available updates.
3.
If the problem persists:
a.
b.
Replace the system-board, as described in Replacing the system-board and chassis assembly.
AA00E1B1
Explanation:
Waiting for the user to accept or decline the license
Response:
1.
Check for server firmware updates.
2.
Apply any available updates.
3.
If the problem persists:
a.
b.
Replace the system-board, as described in Replacing the system-board and chassis assembly.
AA00E1A8 • AA00E1B1
140
Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide
Summary of Contents for P260
Page 1: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Page 2: ......
Page 3: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Page 32: ...20 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 44: ...32 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 46: ...34 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 108: ...96 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 116: ...104 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 512: ...500 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 523: ...Appendix Notices 511 ...
Page 524: ...IBM Printed in USA ...