B7005603
Explanation:
Enclosure feature code and/or serial number not valid.
Response:
Verify that the machine type, model, and serial number are correct for this server.
B7006900
Explanation:
PCI host bridge failure
Response:
1.
Replace the system-board, as described in Replacing the system-board and chassis assembly.
2.
If the problem persists, use the PCI expansion card (PIOCARD) problem isolation procedure to determine the
failing component.
B7006906
Explanation:
System bus error
Response:
Replace the system-board and chassis assembly, as described in Replacing the system-board and chassis
B7006907
Explanation:
System bus error
Response:
1.
Replace the system-board, as described in Replacing the system-board and chassis assembly.
2.
Go to Isolating firmware problems.
B7006908
Explanation:
System bus error
Response:
Replace the system-board and chassis assembly, as described in Replacing the system-board and chassis
B7006909
Explanation:
System bus error
Response:
1.
Replace the system-board, as described in Replacing the system-board and chassis assembly.
2.
Go to Isolating firmware problems.
B7005603 • B7006909
Chapter 8. Troubleshooting
179
Summary of Contents for P260
Page 1: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Page 2: ......
Page 3: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Page 32: ...20 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 44: ...32 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 46: ...34 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 108: ...96 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 116: ...104 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 512: ...500 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 523: ...Appendix Notices 511 ...
Page 524: ...IBM Printed in USA ...