26D2-112
Explanation:
The diagnostic test failed. Replace the 600 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v
26D2-114
Explanation:
An unrecoverable hardware error. Replace the 600 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v
26D2-116
Explanation:
A protocol error.
1.
Make sure that the firmware of the FRUs shown and the parent adapter, are compatible with the diagnostic and
application software levels.
2.
If you do not find a problem, call your operating-system support person.
Response:
Failing Item:
v
26D2-117
Explanation:
A write-protect error occurred. Replace the 600 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v
26D2-118
Explanation:
A SCSI command time-out occurred. Replace the 600 GB SFF SAS Hard Disk Drive. Run diagnostics
again on the drive. If the error repeats, replace the 2nd FRU identified by diagnostics.
Response:
Failing Item:
v
v
26D2-112 • 26D2-118
Chapter 8. Troubleshooting
363
Summary of Contents for P260
Page 1: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Page 2: ......
Page 3: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Page 32: ...20 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 44: ...32 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 46: ...34 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 108: ...96 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 116: ...104 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 512: ...500 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 523: ...Appendix Notices 511 ...
Page 524: ...IBM Printed in USA ...