B700F108
Explanation:
A firmware error caused the system to terminate.
Response:
1.
Collect the event log information.
2.
Go to Isolating firmware problems.
B700F10A
Explanation:
System firmware detected an error
Response:
Look for and correct B1xxxxxx errors.
B700F10B
Explanation:
A processor resource has been disabled due to hardware problems
Response:
Replace the system-board and chassis assembly, as described in Replacing the system-board and chassis
B700F10C
Explanation:
The platform LIC detected an internal problem performing Partition Mobility.
Response:
1.
Collect the event log information.
2.
Go to Isolating firmware problems.
B700F120
Explanation:
Informational system log entry only.
Response:
No corrective action is required.
B700F130
Explanation:
Thermal Power Management Device firmware error was detected.
Response:
Check for server firmware updates; then, install the updates if available.
BAxxyyyy partition firmware SRCs:
The power-on self-test (POST) might display an error code that the partition firmware detects. Try to
correct the problem with the suggested action.
B700F108 • B700F130
Chapter 8. Troubleshooting
189
Summary of Contents for P260
Page 1: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Page 2: ......
Page 3: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Page 32: ...20 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 44: ...32 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 46: ...34 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 108: ...96 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 116: ...104 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 512: ...500 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 523: ...Appendix Notices 511 ...
Page 524: ...IBM Printed in USA ...