11008414
Explanation:
Invalid processor 2 VPD.
Response:
1.
Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
2.
Replace the system board. If there is more than one system board, use the location code in the SRC to identify
which system board to replace.
11008423
Explanation:
No processor VPD was found.
Response:
1.
Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
2.
Replace the base system-board, as described in Replacing the system-board and chassis assembly.
11008447
Explanation:
SSD interposer card pGood fault on the system board.
Response:
1.
Replace the interposer card specified by the location code in the error log entry.
11008480
Explanation:
Bad or missing memory controller.
Response:
1.
Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
2.
Replace the system board. If there is more than one system board, use the location code in the SRC to identify
which system board to replace.
110084A0
Explanation:
No backplane VPD was found.
Response:
1.
Check for server firmware updates.
2.
Apply any available updates.
3.
Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
4.
Replace the base system-board, as described in Replacing the system-board and chassis assembly.
6xxxyyyy SRCs:
The 6xxxyyyy system reference codes are virtual optical reference codes.
Find the system reference code in the list below. Follow the suggested actions in the order in which they
are listed until the problem is solved. If an action solves the problem, then you can stop performing the
remaining actions. See Chapter 7, “Parts listing for IBM Flex System p260 and p460 Compute Nodes,” on
page 97 to determine which components are CRUs and which components are FRUs.
11008414 • 110084A0
128
Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide
Summary of Contents for P260
Page 1: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Page 2: ......
Page 3: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Page 32: ...20 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 44: ...32 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 46: ...34 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 108: ...96 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 116: ...104 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 512: ...500 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 523: ...Appendix Notices 511 ...
Page 524: ...IBM Printed in USA ...