1100265A
Explanation:
1.2VA pGood fault
Response:
1.
Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
2.
Replace the system board. If there is more than one system board, use the location code in the SRC to identify
which system board to replace.
11002671
Explanation:
12V power fault in the server.
Response:
1.
Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
2.
Replace the system board. If there is more than one system board, use the location code in the SRC to identify
which system board to replace.
11002672
Explanation:
CFFh expansion card voltage alert.
Response:
Perform the DTRCARD symbolic CRU isolation procedure by completing the following steps:
1.
Reseat the PCIe expansion card.
2.
If the problem persists, replace the expansion card.
3.
If the problem persists, go to the Search RETAIN tips and the firmware change history for the reference code to
determine the recommended actions. If a firmware update is needed, see Updating the firmware.
4.
If the problem persists, replace the system-board into which the expansion card was plugged.
The DTRCARD symbolic CRU isolation procedure is in Service processor problems.
11002673
Explanation:
Standby power fault on one of the system-boards in the server.
Response:
1.
Check the management module event log for entries that indicate a power problem with the chassis unit.
2.
Resolve any problems.
3.
Remove the server from the chassis, then reinsert it.
4.
Power on the server.
5.
Monitor the server operation to verify that the problem is solved.
6.
If the chassis unit is functioning normally, but the problem persists, replace the system board specified by the
location code that was reported with the SRC.
1100265A • 11002673
122
Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide
Summary of Contents for P260
Page 1: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Page 2: ......
Page 3: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Page 32: ...20 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 44: ...32 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 46: ...34 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 108: ...96 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 116: ...104 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 512: ...500 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 523: ...Appendix Notices 511 ...
Page 524: ...IBM Printed in USA ...