B7000441
Explanation:
Service processor failure. The platform encountered an error early in the startup or termination
process.
Response:
Replace the system-board and chassis assembly, as described in Replacing the system-board and chassis
B7000443
Explanation:
Service processor failure.
Response:
Replace the system-board and chassis assembly, as described in Replacing the system-board and chassis
B7000601
Explanation:
Informational system log entry only.
Response:
No corrective action is required.
Note: This code and associated data can be used to determine why the time of day for a partition was lost.
B7000602
Explanation:
System firmware detected an error condition.
Response:
1.
Collect the event log information.
2.
Go to Isolating firmware problems.
B7000611
Explanation:
There is a problem with the system hardware clock; the clock time is invalid.
Response:
Use the operating system to set the system clock.
B7000621
Explanation:
Informational system log entry only.
Response:
No corrective action is required.
B7000641
Explanation:
System firmware detected an error.
Response:
1.
Collect the platform dump information.
2.
Go to Isolating firmware problems.
B7000441 • B7000641
Chapter 8. Troubleshooting
171
Summary of Contents for P260
Page 1: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Page 2: ......
Page 3: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Page 32: ...20 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 44: ...32 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 46: ...34 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 108: ...96 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 116: ...104 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 512: ...500 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 523: ...Appendix Notices 511 ...
Page 524: ...IBM Printed in USA ...