268B-136
Explanation:
The certify operation failed. Replace the 300 GB SFF SAS Hard Disk Drive.
Response:
Failing Item:
v
268B-137
Explanation:
Unit attention condition has occurred on the Send Diagnostic command. Replace the 300 GB SFF SAS
Hard Disk Drive. Run diagnostics again on the drive. If the error repeats, replace the 2nd FRU identified by
diagnostics.
Response:
Failing Item:
v
v
268B-138
Explanation:
Error log analysis indicates that the disk drive is operating at a higher than recommended
temperature.
1.
Make sure that:
v
The ventilation holes in the blade server bezel are not blocked.
v
The Management Module event log is not reporting any system environmental warnings.
2.
If the problem remains, call IBM support.
Response:
Failing Item:
v
268B-140
Explanation:
Error log analysis indicates poor signal quality. Replace each part reported by the diagnostic program
one at a time. Run the diagnostic program in problem determination mode on each part reported in the original SRN.
If the problem persists, replace the next part in the list.
Response:
Failing Item:
v
v
268B-136 • 268B-140
Chapter 8. Troubleshooting
355
Summary of Contents for P260
Page 1: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Page 2: ......
Page 3: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Page 32: ...20 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 44: ...32 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 46: ...34 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 108: ...96 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 116: ...104 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 512: ...500 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 523: ...Appendix Notices 511 ...
Page 524: ...IBM Printed in USA ...