B2001260
Explanation:
A problem occurred during the startup of a partition.
The partition could not start at the Timed Power On setting because the partition was not set to Normal.
Response:
Set the partition to Normal.
B2001265
Explanation:
The partition could not start up. An operating system Main Storage Dump startup was attempted with
the startup side on D-mode, which is not a valid operating system startup scenario. The startup will be halted. This
SRC can occur when a D-mode SLIC installation fails and attempts a Main Storage Dump.
Response:
Correct the startup settings.
B2001266
Explanation:
The partition could not start up. You are attempting to start up an operating system that is not
supported.
Response:
Install a supported operating system and restart the partition.
B2001280
Explanation:
A problem occurred during a partition Main Storage Dump. A mainstore dump startup did not
complete due to a configuration mismatch.
Response:
Go to Isolating firmware problems.
B2001281
Explanation:
A partition memory error occurred. The failed memory will no longer be used.
Response:
Restart the partition.
B2001282
Explanation:
A problem occurred during the startup of a partition.
Response:
Go to Isolating firmware problems.
B2001320
Explanation:
A problem occurred during the startup of a partition.
No default load source was selected. The startup will attempt to continue, but there may not be enough information
to find the correct load source.
Response:
Configure a load source for the partition. Then restart the partition.
B2001260 • B2001320
Chapter 8. Troubleshooting
149
Summary of Contents for P260
Page 1: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Page 2: ......
Page 3: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Page 32: ...20 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 44: ...32 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 46: ...34 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 108: ...96 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 116: ...104 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 512: ...500 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 523: ...Appendix Notices 511 ...
Page 524: ...IBM Printed in USA ...