Table 9. IBM Flex System p460 Compute Node parts (continued)
Index Description
CRU part number
FRU part
number
Failing
function
code (FFC)
(Tier 1)
(Tier 2)
1
IBM Flex System 8-port 10 Gb converged adapter
00E1677
2E28, 2E52
1
IBM Flex System 2-port 10 Gb RoCE adapter
90Y3481
2770
1
IBM Flex System 2-port 16 Gb Fibre Channel adapter
95Y2389
2750
1
IBM Flex System 4-port 16 Gb Fibre Channel adapter
95Y2394
2755
2
7895-42X management card:
v
Management card (CCIN 52E9) for 3.3 GHz, 16-core
system board
v
Management card (CCIN 52EB) for 3.2 GHz, 32-core
system board
v
Management card (CCIN 52E7) for 3.5 GHz, 32-core
system board
v
00E0703
v
00E0702
v
00E0701
2
7895-43X management card:
v
Management card (CCIN 52F8) for 4.0 GHz, 16-core
system board
v
Management card (CCIN 523F) for 3.6 GHz, 32-core
system board
v
Management card (CCIN 521B) for 4.1 GHz, 32-core
system board
v
00E2232
v
00E2885
v
00E2226
3
Light path diagnostics panel
81Y5290
4
Bezel
00E5817
4
OEM bezel
00E5818
5
Thermal sensor
44X1464
6
3.0V battery
33F8354
7
Memory, 2 GB DDR3, 1066 MHz low profile (LP)
DIMM
Note:
7895-42X only.
78P1011
7
Memory, 4 GB DDR3, 1066 MHz very low profile (VLP)
DIMM
78P0501
7
Memory, 8 GB DDR3, 1066 MHz very low profile (VLP)
DIMM
Note:
7895-42X only.
78P0502
7
Memory, 8 GB DDR3, 1066 MHz very low profile (VLP)
DIMM
78P1917
7
Memory, 16 GB DDR3, 1066 MHz low profile (LP)
DIMM
Note:
7895-42X only.
78P0639
7
Memory, 16 GB DDR3, 1066 MHz low profile (LP)
DIMM
78P1915
7
Memory, 32 GB DDR3, 1066 MHz low profile (LP)
DIMM
78P1539
7
DIMM filler
60H2962
8
Cover (supports two disk drives)
00J0291
8
Cover (supports two solid-state drives)
00J0293
26BD
8
Cover (no drives supported)
00E6260
102
Power Systems: IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide
Summary of Contents for P260
Page 1: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Page 2: ......
Page 3: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Page 32: ...20 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 44: ...32 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 46: ...34 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 108: ...96 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 116: ...104 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 512: ...500 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 523: ...Appendix Notices 511 ...
Page 524: ...IBM Printed in USA ...