2607-701
Explanation:
Error Log Analysis indicates that the adapter self-test failed for the Fibre Channel adapter card. Go to
Performing the checkout procedure.
Response:
Failing Item:
v
2607-703
Explanation:
Error Log Analysis indicates that an unknown adapter error has occurred for the Fibre Channel
adapter card. Go to Performing the checkout procedure.
Response:
Failing Item:
v
2607-704
Explanation:
Error Log Analysis indicates that an adapter error has occurred for the Fibre Channel adapter card. Go
to Performing the checkout procedure.
Response:
Failing Item:
v
2607-705
Explanation:
Error Log Analysis indicates that a parity error has been detected for the Fibre Channel adapter card.
The adapter must be replaced immediately. Failure to do so could result in data being read or written incorrectly.
Response:
Failing Item:
v
2607-706
Explanation:
Error Log Analysis indicates that a fatal hardware error has occurred for the Fibre Channel adapter
card.
This adapter was successfully taken off-line. It will remain off-line until reconfigured or the system is rebooted. This
adapter must be replaced and not brought back on-line. Failure to adhere to this action could result in data being
read or written incorrectly or in the loss of data.
Response:
Failing Item:
v
2607-701 • 2607-706
Chapter 8. Troubleshooting
341
Summary of Contents for P260
Page 1: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Page 2: ......
Page 3: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Page 32: ...20 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 44: ...32 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 46: ...34 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 108: ...96 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 116: ...104 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 512: ...500 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 523: ...Appendix Notices 511 ...
Page 524: ...IBM Printed in USA ...