1100267F
Explanation:
ETE daughter card pGood fault.
Response:
1.
Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
2.
Replace the ETE daughter card.
1100269C
Explanation:
1.2V A pGood fault.
Response:
1.
Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
2.
Replace the system board. If there is more than one system board, use the location code in the SRC to identify
which system board to replace.
1100269D
Explanation:
1.2V B pGood fault.
Response:
1.
Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
2.
Replace the system board. If there is more than one system board, use the location code in the SRC to identify
which system board to replace.
110026DA
Explanation:
pGood fault on the expansion system board.
Response:
1.
Search RETAIN tips and the firmware change history for the reference code to determine the recommended
actions. If a firmware update is needed, see Updating the firmware
2.
Perform the following:
a.
Replace the expansion system board assembly, as described in Removing the expansion unit.
11002900
Explanation:
SSD drive or SSD interposer card 3.3V pGood fault on the server board.
Response:
1.
On a single-wide server, replace the following, one at a time, until the failure is no longer detected:
a.
The SSD interposer card
b.
The first SSD drive
c.
The second SSD drive
2.
On a double-wide server, replace the following, one at a time, until the failure is no longer detected:
a.
The SSD interposer card on the expansion planar
b.
The first SSD drive on the expansion planar
c.
The second SSD drive on the expansion planar
1100267F • 11002900
Chapter 8. Troubleshooting
125
Summary of Contents for P260
Page 1: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Page 2: ......
Page 3: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Page 32: ...20 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 44: ...32 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 46: ...34 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 108: ...96 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 116: ...104 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 512: ...500 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 523: ...Appendix Notices 511 ...
Page 524: ...IBM Printed in USA ...