B2008152
Explanation:
No active system processors.
Response:
Verify that processor resources are assigned to the partition.
B2008160
Explanation:
A problem occurred during the migration of a partition.
Response:
Contact IBM support.
B2008161
Explanation:
A problem occurred during the migration of a partition.
Response:
Contact IBM support.
B200A100
Explanation:
A partition ended abnormally; the partition could not stay running and shut itself down.
Response:
1.
Check the error logs and take the actions for the error codes that are found.
2.
Go to Isolating firmware problems.
B200A101
Explanation:
A partition ended abnormally; the partition could not stay running and shut itself down.
Response:
1.
Check the error logs and take the actions for the error codes that are found.
2.
Go to Isolating firmware problems.
B200A140
Explanation:
A lower priority partition lost a usable processor to supply it to a higher priority partition with a bad
processor.
Response:
Evaluate the entire LPAR configuration. Adjust partition profiles with the new number of processors
available in the system.
B200B07B
Explanation:
Informational system log entry only.
Response:
No corrective action is required.
B2008152 • B200B07B
Chapter 8. Troubleshooting
163
Summary of Contents for P260
Page 1: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Page 2: ......
Page 3: ...Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide IBM ...
Page 32: ...20 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 44: ...32 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 46: ...34 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 108: ...96 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 116: ...104 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 512: ...500 Power Systems IBM Flex System p260 and p460 Compute Nodes Installation and Service Guide ...
Page 523: ...Appendix Notices 511 ...
Page 524: ...IBM Printed in USA ...