APANTAC, LLC. 

 7556 SW BRIDGEPORT ROAD 

 PORTLAND, OR 97224, USA 

PHONE +1 503 616 3711 

 FAX +1 503 389 7921 

 

[email protected] 

 

WWW.APANTAC.COM 

 

Page 1 of 31 

 

 

 
 

TAHOMA MiniQ 

Multiviewers 

 

 

HARDWARE MANUAL

 

 

                                   

 

 

 

 
Version 1.0 
Dated: November 19, 2012 

 

 

 

© 2012 Apantac LLC - All rights reserved 
 
The contents of this document are provided in connection with Apantac LLC (“Apantac”) products.  Apantac makes no 
representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right 
to make changes to specifications and product descriptions at any time without notice.  

Summary of Contents for TAHOMA MiniQ

Page 1: ...n 1 0 Dated November 19 2012 2012 Apantac LLC All rights reserved The contents of this document are provided in connection with Apantac LLC Apantac products Apantac makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication and reserves the right to make changes to specifications and product descriptions at any time without notice ...

Page 2: ...irs Outside the Warranty Period 5 Disclaimer 5 Operating Environment 5 INTRODUCTION TO TAHOMA MiniQ MULTIVIEWERS 6 HARDWARE 6 TAHOMA MiniQ PRODUCT 7 TECHNICAL SPECIFICATIONS 8 SPECIFICATIONS 11 PRODUCT CONTENTS WHAT S IN THE BOX 14 OPERATION 18 Optional Hardware 18 MiniQ MULTIVIEWER SETUP EXAMPLES 19 ACCESSORIES 24 Standard Accessories 24 Optional Accessories Error Bookmark not defined APPENDIX A ...

Page 3: ...ermission of Apantac LLC 1BCOMPLIANCE INFORMATION The Apantac equipment has been tested to comply with the following FCC Class A This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial env...

Page 4: ...19BLimitation of Liability Apantac s liability under this warranty shall not exceed the purchase price paid for the defective product In no event shall Apantac be liable for any incidental special or consequential damages including without limitation loss of profits for any breach of this warranty If Apantac replaces the defective Product with a replacement Product as provided under the terms of t...

Page 5: ...c offers OPTIONAL Extended Warranty plans that provide continuous coverage for the Product after the expiration of the Warranty Period Please contact an Apantac sales representative for details on the options that are available for your Apantac equipment 21BUServices and Repairs Outside the Warranty Period Apantac makes its best offer to repair products that are outside the warranty period provide...

Page 6: ...he Apantac Tahoma MiniQ Multiviewer Platform consists of the following 4 different sizes of mechanical frames to serve the needs of broadcast professional AV and surveillance markets These frames are width of 1 RU 1 RU RU and 3RU Each Multiviewer frame has a unique IP address which allows a PC laptop to easily connect and configure the display layouts 1 MiniQ Module A quad video processor that all...

Page 7: ...r every SDI video input 1 HDMI DVI extender RJ45 outputs 1 SDI output 8 GPI RJ50 1 IP port RJ45 1 Analog audio monitoring output Phoenix connector The MiniQ modules can be cascaded together with t Link cables to freely configure its Flexible outputs Flexible Outputs Examples Table 1 Flexible outputs Output s 1 2 3 4 5 6 7 8 Inputs 4 4 4 4 4 4 4 4 Inputs 4 4 4 4 4 4 8 Inputs 4 4 4 4 8 8 Inputs 4 4 ...

Page 8: ... CV 50 60Hz Output resolution up to 1920x1200 1080p Digital clock can be synchronized with NTP Up to 30 presets for display layout Presets can be recalled via GPI or ASCII protocol via network Auto detect aspect ratio between 16x9 and 4x3 Communication interface via IP or RS232 Supports Apantac eXtended Protocol AXP Supports direct TSL tally UMD interface Supports multiple languages including 2 by...

Page 9: ...80p 720p 50 1080p 24 2048x1080p 24 576i 720p 59 94 1080p 25 576p 720p 60 1080p 29 97 720p 23 98 1035i 59 94 1080p 30 720p 24 1035i 60 1080sf 23 98 720p 25 1080i 50 1080sf 24 720p 29 97 1080i 59 94 1080sf 30 Table 4 Display Output Standards DVI D HDMI 1 2 3 VGA up to 1920x1200 SDI Connector RJ45 with transmitter BNC Impedance 100Ω 75Ω Table 5 Audio Outputs Type Number type connector Location Adjust...

Page 10: ...support Native to TSL and TSI other third party protocols via Apantac UIM Table 9 Ethernet Network Type Fast Ethernet 100 Base TX Connector RJ45 Cable Auto detect Either straight or crossed cable will work UMD support Native to TSL and TSI other third party protocols via Apantac UIM UIM Universal Interface Module The UIM is a small footprint router protocol translator that acts s a bridge between ...

Page 11: ...APANTAC LLC 7556 SW BRIDGEPORT ROAD PORTLAND OR 97224 USA PHONE 1 503 616 3711 FAX 1 503 389 7921 INFO APANTAC COM WWW APANTAC COM Page 11 of 31 SPECIFICATIONS 24B ...

Page 12: ... BRIDGEPORT ROAD PORTLAND OR 97224 USA PHONE 1 503 616 3711 FAX 1 503 389 7921 INFO APANTAC COM WWW APANTAC COM Page 12 of 31 Figure 1 show the front panel of a single MiniQ Figure 2 show the rear panel of a single MiniQ ...

Page 13: ...LAND OR 97224 USA PHONE 1 503 616 3711 FAX 1 503 389 7921 INFO APANTAC COM WWW APANTAC COM Page 13 of 31 Figure 3 show the front view of a fully configured MiniQ 3U FR frame Figure 4 show the rear view of a fully configured MiniQ 3U FR frame ...

Page 14: ...cable 1 7 HDMI to DVI adapter 1 8 t link cable for cascading 1 9 Terminal block for GPI 1 10 DC Power Supply Optional 11 1 RU Rack Mount Optional Table 11 What s in the box MiniQ mouted in MiniQ 3U FR Description QTY 1 MiniQ Modules Up to 8 2 Serial Breakout 1 per MiniQ module 3 Rack mount 1 set of Rack Ears 4 GPI Breakout 1 per MiniQ module 5 Power Supplies 2 6 RJ45 to HDMI cable 1 per MiniQ modu...

Page 15: ...l Installation MiniQ can be installed in a standard 19 rack using the proper screws and washers not included Tahoma modules are shipped with rack ear These accessories are not installed to ensure proper shipment First locate them in the accessories box and then install them Note The MiniQs airflow is from front to back Figure 5 Rack mount and airflow for Tahoma MiniQ ...

Page 16: ...red as a single unit the default IP address is set to 192 168 1 151 When MiniQ is delivered in the 3 RU frame the default IP address is set to 192 168 1 151 158 from right to left facing the front IP Hub Switch Cascading between MiniQ s Figure 6 Cascading and IP addresses of multiple MiniQ s in a MiniQ 3U FR Direction of Cascading Right to Left 158 157 156 155 154 153 152 151 192 168 1 ...

Page 17: ...M WWW APANTAC COM Page 17 of 31 Power Connection The single MiniQ has 2 DC power connectors to provide redundancy The optional DC power supplies are Universal power supplies for 90 V to 250V operation The MiniQ 3U FR has 2 hot swappable AC power supplies They are universal power supplies for 90V to 250V operation ...

Page 18: ...or auto detect video inputs 16 embedded audio meters per SDI inputs 8 GPI O on the control board for alarms and recalling presets 8 GPI O on the video processing board for tally alarm and recalling presets 1 Ethernet connection for control and configuration 1 RJ45 input for serial connection 1 phoenix on the rear panel for line Level analog audio monitoring 1 RJ45 for DVI HDMI 1 2 1 3 VGA outputs ...

Page 19: ...DGEPORT ROAD PORTLAND OR 97224 USA PHONE 1 503 616 3711 FAX 1 503 389 7921 INFO APANTAC COM WWW APANTAC COM Page 19 of 31 14BMiniQ MULTIVIEWER SETUP EXAMPLES Figure 7 Single MiniQ modules installation with Ethernet connection ...

Page 20: ...LLC 7556 SW BRIDGEPORT ROAD PORTLAND OR 97224 USA PHONE 1 503 616 3711 FAX 1 503 389 7921 INFO APANTAC COM WWW APANTAC COM Page 20 of 31 Figure 8 Multiple MiniQ Modules installation with a MiniQ 1U FR rackmount ...

Page 21: ...TLAND OR 97224 USA PHONE 1 503 616 3711 FAX 1 503 389 7921 INFO APANTAC COM WWW APANTAC COM Page 21 of 31 Figure 9 A fully configured MiniQ in a MiniQ 3U FR frame setup Using t Link to cascade multiple modules together to form a 2 x 16 setup ...

Page 22: ...TLAND OR 97224 USA PHONE 1 503 616 3711 FAX 1 503 389 7921 INFO APANTAC COM WWW APANTAC COM Page 22 of 31 Figure 10 A fully configured MiniQ in a MiniQ 3U FR frame setup Using t Link to cascade multiple modules together to form a 4 x 8 setup ...

Page 23: ...LAND OR 97224 USA PHONE 1 503 616 3711 FAX 1 503 389 7921 INFO APANTAC COM WWW APANTAC COM Page 23 of 31 Figure 11 A fully configured MiniQ in a MiniQ 3U FR frame setup Using t Link to cascade multiple modules together to form a 8 x 14 setup ...

Page 24: ...3711 FAX 1 503 389 7921 INFO APANTAC COM WWW APANTAC COM Page 24 of 31 15BACCESSORIES 30BStandard Accessories Power cord North American customers only GPI breakout on control board RJ50 to DB9 Rack mount RJ45 DB9 converter for RS232 serial connection Terminal Block CD manual ...

Page 25: ... of 31 16APPENDIX A CONNECTORS UBNC Inputs 4 X BNC Connector Auto Detection for SDI and CVBS signal Figure 12 75 ohm BNC Connector UHDMI DVI RJ45 Output Connector 3 differential pairs for data 1 differential pair for clock Total 8 pins Figure 13 RJ45 connector Pin 1 2 3 4 5 6 7 8 Function Clk Clk Data 2 Data 1 Data 1 Data 2 Data 0 Data 0 ...

Page 26: ...onnector 3 for RGB 1 for HS 1 for VS Others are GND Total 8 pins Pin 1 2 3 4 5 6 7 8 Function VS HS BLUE GND GREEN GND RED GND U RS232 RJ45 Connector 1 pin for Tx 1 pin for Rx 3 pins for 5V power 3 pins for GND Pin 1 2 3 4 5 6 7 8 Function 5V GND Tx GND Rx GND 5v 5v U GPI I O RJ50 defined GPI I O 8 pins GPI I O 1 power alarm 1 GND Pin 1 2 3 4 5 6 7 8 9 10 Function GPI I O 1 GPI I O 2 GPI I O 3 GPI...

Page 27: ...ORTLAND OR 97224 USA PHONE 1 503 616 3711 FAX 1 503 389 7921 INFO APANTAC COM WWW APANTAC COM Page 27 of 31 Figure 14 RJ50 to DB9 cable Figure 15 GPI IN Wiring diagram Connect this terminal block to the RJ50 to DB9 cable shown in Figure 14 ...

Page 28: ... USA PHONE 1 503 616 3711 FAX 1 503 389 7921 INFO APANTAC COM WWW APANTAC COM Page 28 of 31 Figure 16 GPI OUT Wiring diagram Connect this terminal block to the RJ50 to DB9 cable shown in Figure 33 Note All LED are standard LEDs all resistors are 150 ohms ...

Page 29: ... has been met High frequency design less power consumption CEC law energy efficiency has been met Over voltage protection short circuit protection UInput Voltage Range Universal 100 200 VAC single phase Nominal 100 120 VAC 200 24 VAC Frequency 47 63Hz Current 1 5A Max Inrush Current 30A Max 100VAC 60A Max 240VAC Efficiency 78 minimum 9At normal line voltage full Load UDC Output Voltage 12 00V Curr...

Page 30: ... OC C 40 OC Storage 20 OC C 60 OC Humidity Range non condensing Operating OPERATING 20 80 RH Storage STORAGE 10 90 RH Cooling should operate without fan MTBF 50000 HOURS Min 25OC FULL LOAD MECHANICAL WEIGHT 320g CABLX TYPE UL 1185 18AWG WIRE PLUG BLACK PLUG 5 5 X 2 5 X 10 mm Lock Ring to secure connection CABLX LX NGTH 150 cm CASE DIMENSION 120 mm L x 60mm W x 38mm H EXTERNAL LOOK MATERIAL FLAMMAB...

Page 31: ...M WWW APANTAC COM Page 31 of 31 18BCONTACT APANTAC For troubleshooting support and service as well as upgrades please contact Phone 1 503 616 3711 Email support apantac com Apantac 7556 SW Bridgeport Road Portland OR 97224 USA Phone 1 503 616 3711 Fax 1 503 389 7921 Email HUsupport apantac comU HUwww apantac comU ...

Reviews: