Important
Clearing CMOS memory erases the configuration of your server.
Therefore, you must reconfigure the server after clearing CMOS
memory. If possible, record the configuration information of
your server before moving the CMOS jumper.
Before you begin
Using the Configuration/Setup Utility program, record all
configuration information.
Read “Safety information” on page 70 and “Handling
static-sensitive devices” on page 72.
Turn off the server.
Disconnect the power cord and cables and remove the server
cover (see “Disconnecting cables and removing the cover” on
page 76).
1. Locate the Clear CMOS Request jumper on the system board.
For more information, see “Identifying parts on the system
board” on page 82 or see the label inside the server.
2. Move the jumper from its normal position (pins 1 and 2) to pins
2 and 3. It might be helpful to use needlenose pliers to move
the jumper, but be careful not to damage any system board
components or crush the jumper.
1
2
3
1
2
3
1
2
3
Chapter 5. Installing options
131
Summary of Contents for Netfinity 3500 M10
Page 1: ...Netfinity 3500 M10 User s Handbook...
Page 2: ......
Page 3: ...Netfinity 3500 M10 User s Handbook IBM...
Page 14: ...xii Netfinity 3500 M10 User s Handbook...
Page 18: ...xvi Netfinity 3500 M10 User s Handbook...
Page 80: ...62 Netfinity 3500 M10 User s Handbook...
Page 228: ...210 Netfinity 3500 M10 User s Handbook...
Page 236: ...System board switches 218 Netfinity 3500 M10 User s Handbook...
Page 256: ...238 Netfinity 3500 M10 User s Handbook...
Page 267: ......
Page 268: ...IBM Part Number 37L6687 Printed in U S A July 1999 37L6687...