278
(3) For Teaching Pendant (TB-01)
Press Reset Alm.
Press Trial Operation on the Menu
1 screen.
Press Jog_Inching on Trial
Operation screen.
Touch SV OFF to turn the servo ON
and touch HOME in Jog screen.
Adjustment for Repeatability of Home Position
In case the home position has changed from where it was previously in an absolute reset after
the absolute data has lost, it can be adjusted in Parameter No. 22 Home Return Offset.
Mark the home position on the mechanical side at the first startup. From the position where it
has changed from the original home position after the absolute reset, move the actuator to the
marked position with such an operation as JOG operation. Read the coordinates and add (if the
number is positive, and subtract if negative) them to the values in Parameter No. 22.
(Note) At this time, note the values in Parameter No. 22 before the adjustment so the setting
can be put back in any occasions.
1
2
3
4
Chapter 7
Absolute Reset and
Absolute Battery
Summary of Contents for MCON-C
Page 1: ...MCON C CG Controller Instruction Manual Fourth Edition ...
Page 2: ......
Page 48: ...38 Chapter 1 Specifications Check ...
Page 268: ...258 3 10 Fieldbus Status LEDs ...
Page 274: ...264 Chapter 4 Vibration Suppress Control Function ...
Page 278: ...268 Chapter 5 Collision Detection Feature ...
Page 284: ...274 Chapter 6 Power saving Function ...
Page 292: ...282 Chapter 7 Absolute Reset and Absolute Battery ...
Page 358: ...348 Chapter 9 Troubleshooting ...
Page 474: ...Chapter 10 Appendix 464 ...
Page 478: ......
Page 479: ......