210
[6] Multi-step pressing
Image diagram
No.
Position
[mm]
Velocity
[mm/s]
Accele-
ration
[G]
Decele-
ration
[G]
Pressing
[%]
Thresh-
old
[%]
Positioning
width
[mm]
Zone+
[mm]
Zone-
[mm]
Acceleration/
Deceleration
mode
Incre-
mental
Gain
set
Stop
mode
0
1
0.00
250.00
0.20
0.20
0
0
0.10
0.00
0.00
0
0
0
0
2
50.00
250.00
0.20
0.20
30
0
20.00
0.00
0.00
0
0
0
0
3
50.00
250.00
0.20
0.20
50
0
20.00
0.00
0.00
0
0
0
0
4
Control method
After pressing, the pressing pressure can only be changed in the pressing state.
The method of controlling multi-step pressing is the same as that described in [4] Pressing
operation. Shown below is the explanation with the position table above as an example.
1) Set the weak pressing (30%) in position No.2 and perform the pressing operation.
2) If pressing complete signal PEND is turned ON, start the pressing operation with pressing
pressure (50%) greater than the first pressure set in position No.3.
The position data in position No.3 should be the same as that in position No.2 except the
setting in “Pressing”.
3) To add a pressing step with another pressing pressure, add a sequence consisting of a
position number and a pressing operation.
Position No.1
Position No.2
Position No.3
3.8 Control and functions of Input and output signals of Remote I/O Mode
Summary of Contents for MCON-C
Page 1: ...MCON C CG Controller Instruction Manual Fourth Edition ...
Page 2: ......
Page 48: ...38 Chapter 1 Specifications Check ...
Page 268: ...258 3 10 Fieldbus Status LEDs ...
Page 274: ...264 Chapter 4 Vibration Suppress Control Function ...
Page 278: ...268 Chapter 5 Collision Detection Feature ...
Page 284: ...274 Chapter 6 Power saving Function ...
Page 292: ...282 Chapter 7 Absolute Reset and Absolute Battery ...
Page 358: ...348 Chapter 9 Troubleshooting ...
Page 474: ...Chapter 10 Appendix 464 ...
Page 478: ......
Page 479: ......